EAF Water Cooled Combustion

Description of Project:

The existing water-cooled slider box is experiencing a large amount of leaks at it’s Inconel piping.  This is causing a large amount of repair and maintenance during outages.  Evaluate the slider box to determine if the leaks can be prevented longer term.

Scope of Work:

HOH analyzed the existing slider box and the EAF main baghouse to determine if the leaks are caused by the structural design of the slider box or temperature/flow issues in the main baghouse/slider box system.  Recommendations for new material if better than Inconel can be found.  HOH performed a 3D structural analysis of the slider box and was able to identify structural limitations on the existing system and recommend modifications which should allow the slider box to perform as expected.

Value to Client:

The existing slider box required a large amount of maintenance and consistently experienced water leaks.  Modifications to the slider box could greatly reduce down time and maintenance cost.

Location:

LaPlace, LA

Related Projects

View All

Pickling / Tandem Mill And Continuous Pickling Line

Structural engineering design for an all new cold-rolling facility located in Calvert, Alabama.

Read More

ATI Steel Hot Rolling Processing Facility

HOH provided the structural engineering design for the new Hot Rolling Processing Facility being built in Breckenridge, PA.

Read More

NIPSCO Bailly And RMS WWTP

New 18,000 gpd Sewage Treatment Facility for CLIENT’S Generating Station in Indiana.

Read More